**以前のリビジョンの文書です**

smartctl

START OF INFORMATION SECTION

Model Family: Hitachi Travelstar 7K500 Device Model: Hitachi HTS725050A9A364 Serial Number: 101207PCK404GLG45G5J Firmware Version: PC4OC70E User Capacity: 500,107,862,016 bytes Device is: In smartctl database [for details use: -P show] ATA Version is: 8 ATA Standard is: ATA-8-ACS revision 6 Local Time is: Sun Feb 6 15:15:43 2011 JST SMART support is: Available - device has SMART capability. SMART support is: Enabled

Error SMART Thresholds Read failed: I/O error Smartctl: SMART Read Thresholds failed.

START OF READ SMART DATA SECTION

SMART overall-health self-assessment test result: PASSED

General SMART Values: Offline data collection status: (0x00) Offline data collection activity

                                      was never started.
                                      Auto Offline Data Collection: Disabled.

Self-test execution status: ( 0) The previous self-test routine completed

                                      without error or no self-test has ever
                                      been run.

Total time to complete Offline data collection: ( 645) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate.

                                      Auto Offline data collection on/off support.
                                      Suspend Offline collection upon new
                                      command.
                                      Offline surface scan supported.
                                      Self-test supported.
                                      No Conveyance Self-test supported.
                                      Selective Self-test supported.

SMART capabilities: (0x0003) Saves SMART data before entering

                                      power-saving mode.
                                      Supports SMART auto save timer.

Error logging capability: (0x01) Error logging supported.

                                      General Purpose Logging supported.

Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 131) minutes. SCT capabilities: (0x003d) SCT Status supported.

                                      SCT Error Recovery Control supported.
                                      SCT Feature Control supported.
                                      SCT Data Table supported.

SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTENAME FLAG VALUE WORST THRESH TYPE UPDATED WHENFAILED RAWVALUE 1 RawReadErrorRate 0x000b 100 100 062 Pre-fail Always - 0

2 Throughput_Performance  0x0005   100   100   040    Pre-fail  Offline      -       0
3 Spin_Up_Time            0x0007   100   100   033    Pre-fail  Always       -       2
4 Start_Stop_Count        0x0012   100   100   000    Old_age   Always       -       3
5 Reallocated_Sector_Ct   0x0033   100   100   005    Pre-fail  Always       -       0
7 Seek_Error_Rate         0x000b   100   100   067    Pre-fail  Always       -       0
8 Seek_Time_Performance   0x0005   100   100   ---    Pre-fail  Offline      -       0
9 Power_On_Hours          0x0012   100   100   ---    Old_age   Always       -       0

10 SpinRetryCount 0x0013 100 100 —

Pre-fail  Always       -       0

12 PowerCycleCount 0x0032 100 100 —

Old_age   Always       -       3

191 G-SenseErrorRate 0x000a 100 100 —

Old_age   Always       -       0

192 Power-OffRetractCount 0x0032 100 100 —

Old_age   Always       -       1

193 LoadCycleCount 0x0012 100 100 —

Old_age   Always       -       16

194 TemperatureCelsius 0x0002 229 229 — Oldage Always - 24 (Min/Max 22/27) 196 ReallocatedEventCount 0x0032 100 100 —

Old_age   Always       -       0

197 CurrentPendingSector 0x0022 100 100 —

Old_age   Always       -       0

198 OfflineUncorrectable 0x0008 100 100 — Oldage Offline - 0 199 UDMACRCErrorCount 0x000a 200 200 — Oldage Always - 0 223 LoadRetryCount 0x000a 100 100 —

Old_age   Always       -       0

SMART Error Log Version: 1 No Errors Logged

SMART Self-test log structure revision number 1 No self-tests have been logged. [To run self-tests, use: smartctl -t]

SMART Selective self-test log data structure revision number 1 SPAN MINLBA MAXLBA CURRENTTESTSTATUS

  1        0        0  Not_testing
  2        0        0  Not_testing
  3        0        0  Not_testing
  4        0        0  Not_testing
  5        0        0  Not_testing

Selective self-test flags (0x0):

After scanning selected spans, do NOT read-scan remainder of disk.

If Selective self-test is pending on power-up, resume after 0 minute delay.</code>

os/oi/smartctl/start.1322323899.txt.gz · 最終更新: 2011/11/27 01:11 by yuki